Loading design…
amyleesterling
detailed specs to build a humanoid robot (with kids)
| Reference | Value | Description |
|---|---|---|
| Q4X1 | Banner Q4XFULAF110-Q8 / 97540 | Independent displacement witness only. Pin 2 is parked and must be configured inactive. Pin 5 is not inferred to be identical to pin 3. |
| CBLPS1 | Alpha Wire 881802 - 2C 18 AWG | Unshielded 2C 18 AWG; nominal 5.64 mm OD fits the selected 3.5-7 mm gland arithmetically. Received OD and gland retention required. |
| CBLQ4X1 | Banner BC-M12F5-22-2-SF / 815158 | 2 m 5x22 AWG cordset. Manufacturer wording says shield floating to drain; drain parks only at XQ1.6. |
| PS1 | Keithley 2220-30-1 CH1 ONLY | 24.0 V candidate. Current-limit value, lock and received tests remain SELECTION REQUIRED. CH2 disabled and unconnected. |
| PTCB1 | Phoenix PTCB E1 24DC/0.1A NO / 1464484 | Fixed 0.1 A electronic breaker. Typical 1.2x active limiting is not treated as a guaranteed hard ceiling. Remote contact is deliberately unwired. |
| TEST1 | ISOLATED ANALOG LEAD FIXTURE - SELECTION REQUIRED | Guarded physical lead fixture, touch protection, strain relief and isolation are unresolved. |
| XQ1.1 | Phoenix PT 2,5-QUATTRO / 3209578 | One potential, four push-in connections. Port D has no conductor in the candidate assembly. |
| XQ1.2-XQ1.6 | Phoenix PT 2,5 / 3209510 | Analog output feed-through.,Analog-ground feed-through; not bonded to Q4X 0 V by project wiring.,Drain parking terminal only.,Insulated remote-input parking potential; no external drive.,Protected-positive feed-through terminal. |