| Reference | Value | Description |
|---|---|---|
| FB1 | 04980923ZXT RS_LLEG BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FB2 | 04980923ZXT RS_RLEG BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FB3 | 04980923ZXT RS_LARM BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FB4 | 04980923ZXT RS_RARM BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FB5 | 04980923ZXT RS_WAIST BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FB6 | 04980923ZXT TTL_LDIST_REG BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FB7 | 04980923ZXT TTL_RDIST_REG BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FB8 | 04980923ZXT TTL_HEAD_REG BRANCH HOLDER - FUSE VALUE REQUIRED | Fuse holder is physically selected; exact MIDI fuse, value, interrupt rating, discrimination, conductor, lug, terminal hardware and torque remain selection work. |
| FM0 | LITTELFUSE 04980923ZXT MAIN HOLDER - FUSE VALUE REQUIRED | 58 V MIDI holder with cover and M6 mounting tabs. Fuse value, fuse order code, interrupt rating, coordination, terminal hardware, conductor and torque are not released. |
| JRS_LARM? | WPS-RS-LARM INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
| JRS_LLEG? | WPS-RS-LLEG INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
| JRS_RARM? | WPS-RS-RARM INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
|---|
| JRS_RLEG? | WPS-RS-RLEG INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
|---|
| JRS_WAIST? | WPS-RS-WAIST INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
|---|
| JTTL_HEAD_REG? | REG-TTL-HEAD INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
|---|
| JTTL_LDIST_REG? | REG-TTL-LDIST INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
|---|
| JTTL_RDIST_REG? | REG-TTL-RDIST INPUT BOUNDARY | Field connector remains selection work. The five RS branches land at one-bus WPS boards; the three TTL branches land at separate S18V20F9 regulator inputs and their 9 V outputs must remain isolated. |
|---|
| K1,K2 | SCHNEIDER TESYS DECA LC1D40ABD | Second independent contactor in series, also using all three main poles in series. K1/K2 21-22 mirror contacts form the monitored reset feedback chain. Common-cause analysis, fault-current coordination, coil suppression effects, durability, stopping time and qualified whole-machine validation remain open.,Three main poles are connected in series. Schneider catalog MKTED210011EN v17.1 A5/120-A5/123 lists LC1D40A at 50 A for 24 VDC with one, two or three series poles under its DC-1 and DC-2...DC-5 table conditions. The built-in 21-22 NC auxiliary is mirror certified. HR-30 fault current, actual L/R, durability, regeneration, protection, conductor termination, received-device identity and opening-time validation remain open. |
|---|
| MCU1 | DETERMINISTIC MOTION CONTROLLER BOUNDARY | Motion requires both hardwired permit and a fresh bounded local command. A permit/reset transition alone must leave all branch enables disabled. |
|---|
| MON1 | NON-SAFETY DIAGNOSTIC MONITOR | Auxiliary diagnostics are not part of the safety function and cannot enable motion or bypass E-stop, feedback loop or fresh-command logic. |
|---|
| PS1 | MEAN WELL RSP-500-12 | 230 x 127 x 40.5 mm, 1.3 kg, 12 V/41.7 A evaluation candidate. Final terminal-number mapping, source adjustment lock, inrush, protection, thermal rise and regeneration response remain open. |
|---|
| PS2 | MEAN WELL SD-15A-24 | 78 x 51 x 28 mm, 0.18 kg, 24 V/0.625 A candidate. Pin assignment is from SD-15-SPEC 2024-11-22; loading, protection, grounding and application validation remain open. |
|---|
| RB0 | ROBOT RETURN / FRAME BOUNDARY | Return bus, frame bond and proposed single star point are not finalized. Bond conductor, terminal, location, fault current and jurisdictional treatment require qualified selection. |
|---|
| S0 | IDEC XW DUAL-NC E-STOP FAMILY - ORDER CODE REQUIRED | Dual direct-opening contact family candidate. Exact complete order code, terminal numbering, enclosure and application remain selection work. |
|---|
| S1 | IDEC HW1B-M1F11-G RESET CANDIDATE | Momentary reset is eligibility only. It cannot command motion. Exact terminal IDs and monitored falling-edge behavior require physical verification. |
|---|
| SR1 | PILZ PNOZ s4 750104 | Manual 21396-EN-23 identifies these terminals and supports dual-channel E-stop, monitored start and feedback-loop application examples. Exact circuit mode, PLr/SIL allocation, contact protection, reset proof and validation remain open. |
|---|
| XAC1 | FACILITY AC / PE / DISCONNECT / BRANCH PROTECTION | Mains inlet, disconnect, branch protection, conductors, terminals and Boston jurisdictional installation remain qualified selections. |
|---|
| XPERMIT? | HARDWIRED PERMIT STATUS TO MOTION CONTROLLER | Permit restoration never issues motion. Interface voltage, isolation, test pulses and fault response remain selection and validation work. |
|---|
| XT1A? | PANEL SBS75G - SBS75GBLK | Black genderless three-position housing. P1/P2 project polarity assignment must be permanently keyed, labeled and continuity-tested; ground contact uses 1340G1. Cable, breakaway/retention and shielding remain open. |
|---|
| XT1B? | ROBOT SBS75G - SBS75GBLK | Mating robot-side housing with the same controlled project polarity. Finger-safe state, strain relief, frame bond, flex life and tether trip/breakaway behavior require physical validation. |
|---|