| Reference | Value | Description |
|---|---|---|
| Q1-Q3 | IRF640 | |
| U1-U5,U7 | LR8 | |
| U6 | LM311 | |
| U8 | 4N35 | |
| U9 | NE555P | |
| asdf1 | Conn_01x10_Male | |
| BMS1 | Conn_01x08_Male | |
| C1,C2 | 2.2uF | |
| C3 | 1nF | |
| C4-C6 | 1uF | |
| D1,D2,D4-D7 | 1N5349 | |
| D3 | TVS | |
| dff1 | Conn_01x14_Male | |
| F1 | SMCJ440A | |
| F2 | 1A Fuse | |
| F3 | 3A Fuse | |
| FAN,GND_{AIR1 | Conn_01x04_Male | |
| HV_{PCB1,J1,PRECHARGE2,TEMP1,VI1 | Conn_01x02_Male | |
| IMD1 | Conn_01x06_Male | |
| K1 | PUMP | |
| K2 | FAN_R | |
| K3 | FAN_L | |
| K4 | LV_BATT_FAN | |
| PRECHARGE1 | G2RL-1_12DC | General Purpose Relay, G2RL Series, Power, Non Latching, SPDT, 12 VDC, 12 A RoHS Compliant: Yes |
| PS1 | SPAN02A-12 | Isolated DC/DC Converters 9-18Vin 12Vout 167mA SIP8 Reg Iso |
| PS2 | QHL300300S12 | Isolated DC/DC Converters DC-DC 300W 180-425VDC INPUT 1/4 BRICK |
| R1-R4,R6,R7,R9,R11 | 4.7M | |
| R5 | 1M | |
| R8 | 390k | |
| R10 | 4.7k | |
| R12 | 18k | |
| R13 | 12k | |
| R14,R18 | 10k | |
| R15,R19 | 2k2 | |
| R16 | 1k | |
| R17 | 100k | |
| R20,R21 | 240k |